{"id":5915,"date":"2025-06-02T05:00:45","date_gmt":"2025-06-02T05:00:45","guid":{"rendered":"https:\/\/manzoeyecare.com\/?post_type=product&#038;p=5915"},"modified":"2026-10-22T13:49:48","modified_gmt":"2026-10-22T13:49:48","slug":"visionix-vx-120","status":"publish","type":"product","link":"https:\/\/manzoophthalmic.com\/es\/product\/visionix-vx-120\/","title":{"rendered":"Visionix VX 120+ Dry Eye"},"content":{"rendered":"<p>The Visionix <strong>VX 120+ Dry Eye<\/strong> is a multi-diagnostic wavefront anterior segment analyzer, the first to combine Scheimpflug optical pachymetry, Shack-Hartmann wavefront aberrometry, placido ring corneal topography, and an advanced dry eye screening module that can perform a battery of tests to give you a comprehensive analysis of the patient\u2019s visual health.<\/p>\n<p>El <strong>VX 120+ Dry Eye\u00a0<\/strong> is a revolutionary multi-diagnostic instrument that empowers eye care professionals to deliver exceptional patient care. This advanced platform combines several functions into a single, space-saving unit, streamlining your practice and enhancing your diagnostic capabilities.<\/p>\n<p>&nbsp;<\/p>\n<p><iframe title=\"\" src=\"https:\/\/www.youtube.com\/embed\/GuIp2Q64NqQ\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><br \/>\nImpulsado por <a href=\"https:\/\/youtubeembedcode.com\">youtube embed code<\/a> y <a href=\"https:\/\/allabeviljas.se\/\">sms l\u00e5n som beviljar alla<\/a><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<p>All-in-one testing includes: autorefraction\/keratometry, corneal topography, wavefront corneal aberrometry, wavefront ocular aberrometry, optical pachymetry, retro-illumination, anterior\/posterior corneal elevation maps, non-contact tonometry, and dry eye anterior imaging module.<\/p>\n<p>&nbsp;<\/p>\n<h3>Visionix VX 120+ Features<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>Comprehensive Eye Health Assessment: Screen for and monitor common eye conditions like glaucoma, cataracts, keratoconus, and dry eye syndrome.<\/li>\n<li>Advanced Dry Eye Analysis: The VX-120+ Dry Eye module provides in-depth analysis of tear film stability, meibomian gland function, and tear meniscus height.<\/li>\n<li>Refractive Assessment and Night Vision Correction: Identify and address vision issues, including those affecting night vision, allowing for customized glasses for optimal visual acuity.<\/li>\n<li>Enhanced Patient Care: Provide a more thorough evaluation and personalized recommendations, fostering trust and patient loyalty.<\/li>\n<li>Increased Practice Efficiency:\u00a0 Automate multiple tests and generate detailed reports, saving you valuable time.<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Visionix VX 120+ Benefits<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>Improved Diagnostic Accuracy: Gain a deeper understanding of your patients&#8217; eye health for informed treatment decisions.<\/li>\n<li>Expanded Service Offerings:\u00a0 Distinguish yourself by offering advanced dry eye analysis and night vision correction capabilities.<\/li>\n<li>Enhanced Patient Satisfaction: Deliver exceptional care and empower patients to make informed choices about their vision.<\/li>\n<li>Increased Profitability: Identify opportunities for premium lenses and contact lens fittings.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Screen and monitor eye pathologies inclusive the dry eye syndrome<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>Non-Invasive Tear Breakup Time: A test that processes the movement of the rings on the eye and gives the speed of tear film breakup between two blinks.<\/li>\n<li>Meibomian glands: The color camera allows you to make a photo gallery of the parts of the eye and to focus on the meibomian glands area.<\/li>\n<li>Tear Meniscus value: Using the manual zoom of the color camera, you can measure the height of the tear meniscus to complete the test.<\/li>\n<li><\/li>\n<\/ul>\n<h3>Visionix VX 120+ take care of the visual health of all your patients<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>You will improve your daily practice<\/li>\n<li>You will provide better service and create differentiation<\/li>\n<li>You will have more patients and have the opportunity to sell night glasses<\/li>\n<li>You will receive better trust and an enhanced reputation<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Increase quality of service by using a complete diagnostic tool<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>Distinguish yourself from your competitors and be a recognized vision expert<\/li>\n<li>Reinforce your position as a specialist<\/li>\n<li>Create and\/or increase relationships with ophthalmologists<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Complete examination of the anterior segment of the eye<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>Cataracts: Screening and approving candidates for Premium implants<\/li>\n<li>Refractive: Screening and approving candidates for surgery<\/li>\n<li>Glaucoma: Screening and monitoring<\/li>\n<li>Adaptation of rigid and scleral contact lenses<\/li>\n<li>Keratoconus: Screening, stage classification, and monitoring<\/li>\n<li>Identifying refraction needs that are linked to night vision<\/li>\n<li>Also provides complete readings for refraction and keratometry<\/li>\n<li>Screen and monitor Dry Eye Syndrome (DES)<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Obtain precise measurements and a visual health assessment of the client<\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li>Accurate vision for your patients with customized glasses that may even correct night vision if needed<\/li>\n<li>Create satisfaction and client retention<\/li>\n<li>Reinforce wearer\u2019s feeling of security and trust<\/li>\n<li>Adaptation of premium products<\/li>\n<\/ul>\n<h3><\/h3>\n<h3>Dimensions<\/h3>\n<ul>\n<li>WIDTH: 312 mm (11.28 in.)<\/li>\n<li>DEPTH: 530 mm (20.87 in.)<\/li>\n<li>HEIGHT: 570 mm (22.44 in.)<\/li>\n<li>WEIGHT: 25 kg (55.12 lbs)<\/li>\n<li>VOLTAGE: 100 V \u2013 240 V \/ 50 Hz \u2013 60 Hz, 300 W<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<h3>Visionix VX 120+ Genereal Specification<\/h3>\n<table>\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>Value<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Alignment<\/td>\n<td>XYZ automatic<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>10.1\u201d (1 024 x 600) TFT multi-touch screen<\/td>\n<\/tr>\n<tr>\n<td>Observation area<\/td>\n<td>\u00f8 14 mm<\/td>\n<\/tr>\n<tr>\n<td>Medical device directive<\/td>\n<td>EC MDD 93\/42\/EC modified by directive 2007\/47\/EC<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>RS232 \/ USB \/ VGA \/ LAN<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Power mapping and refraction<\/h3>\n<table>\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>Value<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Spherical power range<\/td>\n<td>-20D to +20D<\/td>\n<\/tr>\n<tr>\n<td>Cylinder power range<\/td>\n<td>0D to + 8D<\/td>\n<\/tr>\n<tr>\n<td>Axis<\/td>\n<td>0 to 180\u00b0<\/td>\n<\/tr>\n<tr>\n<td>Measuring area<\/td>\n<td>Min. \u00f8 2 mm \u2013 Max. 7 mm (3 zones)<\/td>\n<\/tr>\n<tr>\n<td>Number of measuring points<\/td>\n<td>1,300 points<\/td>\n<\/tr>\n<tr>\n<td>Acquisition time<\/td>\n<td>0.2 sec<\/td>\n<\/tr>\n<tr>\n<td>Method<\/td>\n<td>Shack-Hartmann<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<h3>Pachymetry, IC (iridocorneal) angle and pupillometry<\/h3>\n<table>\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>Value<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Method<\/td>\n<td>Continuous horizontal scan with the Scheimpflug camera<\/td>\n<\/tr>\n<tr>\n<td>Pachymeter measuring range<\/td>\n<td>150-1300 \u03bcm<\/td>\n<\/tr>\n<tr>\n<td>Pachymeter resolution<\/td>\n<td>+\/- 10 microns<\/td>\n<\/tr>\n<tr>\n<td>IC angle measuring range<\/td>\n<td>0\u00b0-60\u00b0<\/td>\n<\/tr>\n<tr>\n<td>IC resolution<\/td>\n<td>0.1\u00b0<\/td>\n<\/tr>\n<tr>\n<td>Pupil illumination<\/td>\n<td>Blue light 455 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<h3>Retroillumination, corneal topography by specular reflection<\/h3>\n<table>\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>Value<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Number of rings<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>Number of measuring points<\/td>\n<td>6.144<\/td>\n<\/tr>\n<tr>\n<td>Number of points analyzed<\/td>\n<td>More than 100,000<\/td>\n<\/tr>\n<tr>\n<td>Diameter of covered corneal area at 43D<\/td>\n<td>From 0.75 mm to more than 10 mm<\/td>\n<\/tr>\n<tr>\n<td>Rango de medici\u00f3n<\/td>\n<td>From 37.5 D to 56 D<\/td>\n<\/tr>\n<tr>\n<td>Repeatability<\/td>\n<td>0.02 D<\/td>\n<\/tr>\n<tr>\n<td>Method<\/td>\n<td>Placido rings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<h3>Tonometro<\/h3>\n<table>\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>Value<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Rango de medici\u00f3n<\/td>\n<td>7 mmHg to 44 mmHg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<h3><\/h3>\n<h3>Referencias<\/h3>\n<p>&nbsp;<\/p>\n<h3><a href=\"https:\/\/manzoeyecare.com\/wp-content\/uploads\/2025\/06\/Visionix-VX-120-Brochure.pdf\">Visionix VX 120+ Brochure<\/a><\/h3>\n<p>&nbsp;<\/p>\n<h3><a href=\"https:\/\/www.visionix.com\/product\/vx-120\/\" target=\"_blank\" rel=\"noopener\">Informaci\u00f3n del fabricante<\/a><\/h3>","protected":false},"excerpt":{"rendered":"<p>The Visionix <strong>VX 120+<\/strong> Dry Eye is a multi-diagnostic wavefront anterior segment analyzer, the first to combine Scheimpflug optical pachymetry, Shack-Hartmann wavefront aberrometry, placido ring corneal topography, and an advanced dry eye screening module that can perform a battery of tests to give you a comprehensive analysis of the patient\u2019s visual health.<\/p>","protected":false},"featured_media":5921,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[432],"product_cat":[272],"product_tag":[576],"class_list":["post-5915","product","type-product","status-publish","has-post-thumbnail","product_brand-visionix","product_cat-vision-screener","product_tag-visionix-vx-120-dry-eye","first","instock","shipping-taxable","purchasable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.7 (Yoast SEO v28.8-RC6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Visionix VX 120+ Dry Eye | Manzo Ophthalmic<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/manzoophthalmic.com\/es\/product\/visionix-vx-120\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Visionix VX 120+ Dry Eye\" \/>\n<meta property=\"og:description\" content=\"The Visionix VX 120+ Dry Eye is a multi-diagnostic wavefront anterior segment analyzer, the first to combine Scheimpflug optical pachymetry, Shack-Hartmann wavefront aberrometry, placido ring corneal topography, and an advanced dry eye screening module that can perform a battery of tests to give you a comprehensive analysis of the patient\u2019s visual health.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/manzoophthalmic.com\/es\/product\/visionix-vx-120\/\" \/>\n<meta property=\"og:site_name\" content=\"Manzo Ophthalmic\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-22T13:49:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2025\/05\/Visionix-VX-120.png\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Price\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;10,900.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"Availability\" \/>\n\t<meta name=\"twitter:data2\" content=\"In stock\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/\",\"url\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/\",\"name\":\"Visionix VX 120+ Dry Eye | Manzo Ophthalmic\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/manzoophthalmic.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Visionix-VX-120.png\",\"datePublished\":\"2025-06-02T05:00:45+00:00\",\"dateModified\":\"2026-10-22T13:49:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/#primaryimage\",\"url\":\"https:\\\/\\\/manzoophthalmic.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Visionix-VX-120.png\",\"contentUrl\":\"https:\\\/\\\/manzoophthalmic.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Visionix-VX-120.png\",\"width\":900,\"height\":900,\"caption\":\"Visionix VX 120+\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/product\\\/visionix-vx-120\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/manzoophthalmic.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/manzoophthalmic.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Visionix VX 120+ Dry Eye\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/#website\",\"url\":\"https:\\\/\\\/manzoophthalmic.com\\\/\",\"name\":\"Manzo Ophthalmic\",\"description\":\"Affordable Eye Test Equipment\",\"publisher\":{\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/manzoophthalmic.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":[\"Organization\",\"Place\"],\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/#organization\",\"name\":\"Manzo Ophthalmic\",\"alternateName\":\"Manzo Ophthalmic\",\"url\":\"https:\\\/\\\/manzoophthalmic.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/manzoophthalmic.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Manzo-Logo.png\",\"contentUrl\":\"https:\\\/\\\/manzoophthalmic.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Manzo-Logo.png\",\"width\":500,\"height\":500,\"caption\":\"Manzo Ophthalmic\"},\"image\":{\"@id\":\"https:\\\/\\\/manzoophthalmic.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"publishingPrinciples\":\"https:\\\/\\\/manzoophthalmic.com\\\/about\\\/\",\"hasMerchantReturnPolicy\":{\"@type\":\"MerchantReturnPolicy\",\"merchantReturnLink\":\"https:\\\/\\\/manzoophthalmic.com\\\/es\\\/refund\\\/\"},\"telephone\":[\"+ 65 6733 51888\"],\"contactPoint\":{\"@type\":\"ContactPoint\",\"telephone\":\"+ 65 6733 51888\",\"email\":\"sales@manzoophthalmic.com\"},\"email\":\"sales@manzoophthalmic.com\"}]}<\/script>\n<meta property=\"product:brand\" content=\"Visionix\" \/>\n<meta property=\"product:price:amount\" content=\"10900.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:retailer_item_id\" content=\"Visionix VX 120+\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Visionix VX 120+ Dry Eye | Manzo Ophthalmic","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/manzoophthalmic.com\/es\/product\/visionix-vx-120\/","og_locale":"es_ES","og_type":"article","og_title":"Visionix VX 120+ Dry Eye","og_description":"The Visionix VX 120+ Dry Eye is a multi-diagnostic wavefront anterior segment analyzer, the first to combine Scheimpflug optical pachymetry, Shack-Hartmann wavefront aberrometry, placido ring corneal topography, and an advanced dry eye screening module that can perform a battery of tests to give you a comprehensive analysis of the patient\u2019s visual health.","og_url":"https:\/\/manzoophthalmic.com\/es\/product\/visionix-vx-120\/","og_site_name":"Manzo Ophthalmic","article_modified_time":"2026-10-22T13:49:48+00:00","og_image":[{"width":900,"height":900,"url":"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2025\/05\/Visionix-VX-120.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Price":"&#36;10,900.00","Availability":"In stock"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/","url":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/","name":"Visionix VX 120+ Dry Eye | Manzo Ophthalmic","isPartOf":{"@id":"https:\/\/manzoophthalmic.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/#primaryimage"},"image":{"@id":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/#primaryimage"},"thumbnailUrl":"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2025\/05\/Visionix-VX-120.png","datePublished":"2025-06-02T05:00:45+00:00","dateModified":"2026-10-22T13:49:48+00:00","breadcrumb":{"@id":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/#primaryimage","url":"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2025\/05\/Visionix-VX-120.png","contentUrl":"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2025\/05\/Visionix-VX-120.png","width":900,"height":900,"caption":"Visionix VX 120+"},{"@type":"BreadcrumbList","@id":"https:\/\/manzoophthalmic.com\/product\/visionix-vx-120\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/manzoophthalmic.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/manzoophthalmic.com\/shop\/"},{"@type":"ListItem","position":3,"name":"Visionix VX 120+ Dry Eye"}]},{"@type":"WebSite","@id":"https:\/\/manzoophthalmic.com\/#website","url":"https:\/\/manzoophthalmic.com\/","name":"Manzo Oftalmol\u00f3gico","description":"Equipo de pruebas oculares asequible","publisher":{"@id":"https:\/\/manzoophthalmic.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/manzoophthalmic.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":["Organization","Place"],"@id":"https:\/\/manzoophthalmic.com\/#organization","name":"Manzo Oftalmol\u00f3gico","alternateName":"Manzo Ophthalmic","url":"https:\/\/manzoophthalmic.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/manzoophthalmic.com\/#\/schema\/logo\/image\/","url":"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2026\/10\/Manzo-Logo.png","contentUrl":"https:\/\/manzoophthalmic.com\/wp-content\/uploads\/2026\/10\/Manzo-Logo.png","width":500,"height":500,"caption":"Manzo Ophthalmic"},"image":{"@id":"https:\/\/manzoophthalmic.com\/#\/schema\/logo\/image\/"},"publishingPrinciples":"https:\/\/manzoophthalmic.com\/about\/","hasMerchantReturnPolicy":{"@type":"MerchantReturnPolicy","merchantReturnLink":"https:\/\/manzoophthalmic.com\/es\/refund\/"},"telephone":["+ 65 6733 51888"],"contactPoint":{"@type":"ContactPoint","telephone":"+ 65 6733 51888","email":"sales@manzoophthalmic.com"},"email":"sales@manzoophthalmic.com"}]},"product_brand":"Visionix","product_price_amount":"10900.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_retailer_item_id":"Visionix VX 120+","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/product\/5915","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/comments?post=5915"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/media\/5921"}],"wp:attachment":[{"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/media?parent=5915"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/product_brand?post=5915"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/product_cat?post=5915"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/manzoophthalmic.com\/es\/wp-json\/wp\/v2\/product_tag?post=5915"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}